E44-157 · Excessive Piping Resistance & Pressure Drop · Process line with many elbows · ★★
Twelve 90° elbows (ζ=0.75) accumulated a local loss of Σζv²/2g=6.3m against the design allowance, and the pump surged
[Accumulated Local Resistance] Many elbows give a large Σζ.
[Exceeds Design] The local loss of 6.3m exceeds the allowance.
[Design Omission] The local resistance was not calculated and long-radius bends were not used, so it exceeds the allowance.
1) Reduce the number of elbows or use long-radius bends (R≥1.5D) to lower ζ, because 12 elbows with Σζ=0.75 accumulate a loss of 6.3m and exceed the allowance, thereby reducing the resistance;
2) Check the local resistance Σζv²/2g against the allowance, because the local loss exceeds the allowance, thereby calculating and controlling it;
3) Optimise the pipe routing to reduce the elbows, because many elbows give a large resistance, thereby reducing the elbows by better routing;
4) Leave head margin in the pump for the local resistance, because the local loss accounts for a large share, thereby keeping the margin;
5) Issue a local resistance calculation sheet, because the original design omitted the calculation, thereby leaving a record;
6) Measure the system resistance during commissioning and match it against the pump, because the design requirement must be verified by measurement, thereby closing out the acceptance;
7) Provide supports and hangers at the elbows to control vibration, because the local loss creates vortex vibration, thereby stabilising the installation;
8) Include the local resistance in the network calculation, because the original omission is the root cause of the excess, so the calculation must include it.
GB/T 20801-2020 Pressure Piping Code