E44-471 · Filter Clogging and Contamination · Coolant Filter 50μm · ★★
Machine-tool coolant chips plug the screen, flow drops, Δp=0.1MPa, tool temperature rises, and workpiece roughness deteriorates
[Mechanism] Metal chips wrap around and tangle in the screen openings.
[Calculation] Chips with length > the screen openings bridge and plug them; effective area shrinks 50%, v=Q/A doubles, and Δp=0.1.
[Design Omission] No magnetic separator to remove long chips first and no backwash, so the screen plugged.
1) Add a magnetic separator upstream to remove long chips first; since chips bridged, area shrank 50%, and Δp=0.1, removing them first keeps flow open;
2) Add timed automatic backwashing; since buildup causes plugging, backwashing cleans it;
3) Change the screen openings to long slots to resist tangling; since round holes tangle chips, slots avoid it;
4) Add agitation in the coolant tank to prevent settling; since settling causes plugging, agitation prevents it;
5) Add a low-flow alarm; since plugging drops flow, the alarm warns;
6) Skim oil regularly to prevent chips from sticking; since oil makes chips adhere, skimming removes it;
7) Maintain coolant concentration per spec to avoid thickening; since thick fluid plugs the screen, concentration control prevents it;
8) Write chip removal and backwashing into the machine procedure; since chips were never removed, the root cause of plugging, the machine procedure provides the check.
GB/T 26114-2010 Filters for liquid filtration