E44-470 · Filter Clogging and Contamination · Compressed-Air Oil-Removal Element · ★★
The oil-removal element saturated; outlet oil content reached 8mg/m³>1mg/m³, pneumatic valves jammed, and products became oil-contaminated
[Mechanism] The glass-fiber coalescing layer absorbed oil until saturated and could no longer remove it.
[Calculation] Oil capacity M=200mL; cumulative loading reached 300mL beyond capacity, oil-removal efficiency dropped from 99% to 60%, and outlet oil reached 8mg.
[Design Omission] No replacement interval set and no oil monitoring, so the element saturated and failed.
1) Set the replacement interval from the oil capacity M=200mL; since 300mL exceeded capacity, efficiency fell to 60%, and outlet reached 8mg, replacement on schedule restores efficiency;
2) Add outlet oil-mist monitoring for <1mg; since exceeding it means failure, oil is monitored;
3) Add an upstream centrifugal water/oil separator; since the load was heavy, pre-treatment reduces it;
4) Run two elements in rotation to keep service continuous; since swapping would interrupt flow, rotation avoids shutdown;
5) Cool and dehumidify at the inlet; since moisture reduces capacity, dehumidification preserves it;
6) Replace as soon as differential pressure rises; since saturation raises Δp, replacement follows Δp;
7) Add a fine filter ahead of the valves as a backstop; since oil damages valves, the backstop protects them;
8) Write the replacement interval into the compressed-air maintenance plan; since no interval was set, the root cause of saturation, maintenance provides the check.
GB/T 14295-2019 Air filters