E44-010 · Seal Leakage · Pump Mechanical Seal · ★★★
Mechanical seal face leakage was 8mL/h (allowable ≤3); the drain sump was emptied twice a month, and it failed after 2000h.
[Face Contact Pressure] The face pressure p=Fs/A+Δp; spring-force decay drops p <0.3MPa, too low to form a liquid-film seal.
[Dry Running] Insufficient face pressure causes dry friction between faces, wear of 0.05mm/1000h, and rising leakage.
[Design Omission] The face pressure was not checked against 0.3~0.6MPa and no flushing was set — low pressure caused the leak.
1) Check the face pressure p=Fs/A+Δp and hold 0.3~0.6MPa; p <0.3 gives no liquid film and dry-runs, while p >0.6 overloads the faces, so take the mid-range to keep the film and resist wear;
2) Choose corrosion-resistant springs and measure the force periodically; corrosion decays Fs and drops p below 0.3, so keep spring force long-term;
3) Provide flush or barrier fluid to ensure the face film; the film is the sealing medium and its absence causes dry running and leakage, so force feed a film;
4) Monitor seal-chamber pressure and temperature online; p and temperature directly set the face pressure and film state, so alarm on anomaly;
5) Pair a silicon-carbide rotating ring with a carbon stationary ring; the hardness difference and self-lubrication minimize wear, extending life to 2000h;
6) Control installation compression against over-tightening; over-compression drives p >0.6 and overheats the faces, so install to the design compression mark;
7) Run a bench seal test on the first unit to ≤3mL/h leakage (was 8); the test is the hard criterion of seal performance, so ship it meeting spec;
8) Bring face-pressure check into seal selection; the unchecked pressure was the root cause of low loading, so calculate it at selection.
GB/T 6556-2016 Mechanical seals - Technical conditions