E44-148 · Other · Sampling Cooler · ★★
Started up without opening cooling water; the tubes ran dry, wall temperature surged, and the cooler ruptured and leaked.
[Dry Run] No cooling makes the wall temperature surge past the material limit.
[Rupture] Thermal stress exceeding the limit causes cracking.
[Design Omission] No interlock to supply water first, and no flow control; the dry run cracked it.
1) Supply cooling water before feeding the sampling cooler; a dry run surges tube temperature and ruptures, so water first, feed next;
2) Interlock a cooling-water flow switch to stop the feed; no flow means a dry run, so the interlock keeps water;
3) Fit a filter on the cooling-water line to prevent blockage and loss of flow; blockage stops water and causes a dry run, so filtering keeps flow;
4) Alarm and trip on a wall-temperature sensor; exceeding the material limit cracks it, so temperature monitoring trips it;
5) Size by medium temperature with margin; a small margin easily overruns, so leave margin;
6) Periodically check that cooling-water passages are clear; they block gradually, so check periodically;
7) Verify water flow on commissioning before feeding; design requirements need measured confirmation, so confirm at delivery;
8) Bring the water-first rule into the operating card; the original failure to open water was the root cause of the dry run, so the procedure must include it.
GB/T 151-2014 Heat exchangers