Viscosity-Induced Flow Deviation

E44-744 · Uneven Flow Distribution · Viscosity · ★★

Problem Description

Viscosity-induced deviation, flow variation

Root Cause

[Mechanism] A change in viscosity deviates the flow.
[Calculation] The change in viscosity causes the deviation.
[Design Omission] No viscosity control, no compensation, and no inspection were provided, so the viscosity varies.

Corrective Solution

1) Keep the medium viscosity steady (temperature control plus mixing, μ fluctuation ≤3%), because the original viscosity change made the branch flows deviate by >10%, thereby controlling viscosity and evening the flow;
2) Add viscosity compensation (online viscometer plus compensation), because changing conditions cause deviation and compensation restores accuracy, thereby compensating;
3) Verify the viscosity parameters (μ vs T curve, accurate), because a deviation means variation and verification restores accuracy, thereby verifying the viscosity;
4) Select an instrument suited to the viscosity (shear-compensated flowmeter), because changing conditions cause deviation and a suitable instrument restores accuracy, thereby matching the instrument to the viscosity;
5) Monitor the deviation (a meter on each branch, alarm above 5%), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
6) Limit the rate of viscosity change (≤2%/min), because abrupt change causes deviation and limiting slows it, thereby limiting the change;
7) Run a flow test (measure each branch, accept when even), because the lack of testing caused the deviation and testing verifies it, thereby testing the flow;
8) Write the viscosity control and compensation into the specification (compensation formula), because the missing control was the root cause and freezing it into the specification enforces control.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping