Knowledge Base › Fluid Systems Error Case › Temperature-Induced Density Change Causing Flow Deviation

Temperature-Induced Density Change Causing Flow Deviation

E44-743 · Uneven Flow Distribution · Temperature · ★★

Problem Description

Temperature-induced deviation, density change

Root Cause

[Mechanism] A temperature change changes the density and deviates the flow.
[Calculation] The change in viscosity causes the deviation.
[Design Omission] No compensation, no control, and no inspection were provided, so the density changes.

Corrective Solution

1) Add temperature and density compensation (online densitometer plus temperature compensation, Δρ compensation), because the original temperature change altered the density and made the branch flows deviate by >8%, thereby compensating the density and evening the flow;
2) Control the temperature against change (temperature control ±1℃), because changing conditions cause deviation and control steadies them, thereby controlling the temperature;
3) Verify the density parameters (ρ vs T curve, accurate), because a deviation means variation and verification restores accuracy, thereby verifying the density;
4) Select an instrument with temperature compensation (flowmeter with temperature and pressure compensation), because cold conditions cause deviation and compensation restores accuracy, thereby compensating for temperature;
5) Monitor the deviation (a meter on each branch, alarm above 5%), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
6) Limit the temperature change rate (≤1℃/min), because abrupt change causes deviation and limiting slows it, thereby limiting the change;
7) Run a heat-balance calculation (heat balance of each branch, accept when balanced), because the missing calculation caused the deviation and calculating verifies it, thereby running the balance calculation;
8) Write the compensation and temperature control into the specification (compensation formula), because the missing compensation was the root cause and freezing it into the specification enforces control.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »