E44-540 · Heat Exchanger Fouling and Insufficient Heat Exchange · Tubular Injection-Molding Barrel Cooling · ★★
Water scale adhesion, reduced K, rising barrel temperature, part deformation
[Mechanism] Hard water scale deposits on the surface.
[Calculation] Rf=0.3 lowers K by 30%, raises barrel temperature by 8℃, and causes part deformation.
[Design Omission] No water softening and no cleaning schedule, so scale formed.
1) Soften the cooling water (hardness ≤60mg/L as CaCO₃) and use scale inhibitors; because hard-water Ca/Mg forms scale, Rf=0.3 lowers K by 30%, raises barrel temperature by 8℃ and causes plastic part deformation, softening suppresses scale, restores K and stabilizes barrel temperature;
2) Schedule descaling (quarterly acid cleaning, flush at Δp>0.08MPa); because scale thickens and K drops before temperature rise becomes visible, periodic descaling restores flow area;
3) Add a barrel-temperature alarm (alarm at barrel temperature > design +6℃); because fouling lowers K first as a barrel-temperature rise and part deformation, it gives early warning;
4) Raise flow velocity (≥1.2m/s) to prevent settling; because hard scale settles in low-velocity zones, higher velocity reduces residence time and suppresses settling;
5) Dose scale inhibitor (proportion to makeup water, concentration ratio ≤3); because crystal nuclei attach to walls and the dispersant suppresses crystallization, hard scale growth is inhibited;
6) Add side-stream filtration (5-10% of circulating flow) to reduce suspended solids; because suspended particles act as scale nuclei, cutting the load suppresses fouling;
7) Inspect scale thickness on schedule (bi-monthly thickness measurement); because scale thickens and worsens K loss and barrel-temperature rise, quantifying it guides descaling;
8) Write softening and descaling into the injection-molding cooling procedure; because the original design omitted softening and descaling, the root cause of hard scale, the procedure closes the loop.
GB/T 151-2014 Heat exchangers