E44-801 · Piping Supports and Thermal Expansion · Vibration-Damping Support · ★★
Damper failed, amplitude >0.2mm, vibration
[Mechanism] Aging / detachment of the damping element makes it fail and the vibration grow.
[Calculation] The failure drives the amplitude >0.2mm and disturbs the adjacent equipment.
[Design Omission] The element was neither replaced nor the frequency tuned — so it must be replaced.
1) Replace the damping element (replace the aged rubber / spring isolator): because the original failure drove the amplitude >0.2mm and disturbed the adjacent equipment, replacing it reduces the vibration;
2) Tune the damping frequency to avoid resonance (keep the natural frequency ≥20% away from the excitation frequency): because resonance amplifies and tuning avoids it, the frequency is tuned;
3) Check the damping parameters (stiffness / damping matched to the pipe weight): because a mismatch vibrates and the check ensures compliance, the parameters are checked;
4) Add damping (a damper raises the damping ratio ≥0.1): because without it vibration grows and damping suppresses it, damping is added;
5) Monitor the vibration condition (measure the amplitude, alarm at >0.15mm): because progressive vibration loosens parts and early awareness helps, vibration is monitored;
6) Perform a vibration test (start up and record the amplitude spectrum): because the original lack of testing left the growth undiscovered, the test identifies the resonance points, so vibration is tested;
7) Control the excitation source (keep the speed away from critical): because the source vibrates and control relieves it, the source is controlled;
8) Write the element replacement and frequency tuning into the maintenance card: the original lack of replacement was the root cause of the vibration, so maintenance controls the work and the amplitude is acceptable.
GB/T 17116.1-2018 Pipe supports and hangers