Large Pipe Span Deflection

E44-802 · Piping Supports and Thermal Expansion · Span · ★★

Problem Description

Span too large, deflection >40mm, sagging

Root Cause

[Mechanism] An excessive span makes the deflection exceed the limit.
[Calculation] The excessive span drives the deflection >40mm (allowable ≤L/200).
[Design Omission] The span was neither calculated nor supports added — so it must be calculated.

Corrective Solution

1) Calculate the span and add supports (set the span for deflection ≤L/200 and cut the span by 20%): because the original large span drove the deflection >40mm above the allowable and sagged the pipe, the span is calculated and supports added;
2) Check the mid-span deflection (measure it and check ≤L/200): because excess sags and the check reveals it, the deflection is checked;
3) Add intermediate piers (add supports per the calculation): because a large span sags and added piers reduce it, piers are added;
4) Raise the pipe stiffness (switch to a thicker wall / one size larger): because a soft pipe sags and raising stiffness hardens it, the stiffness is raised;
5) Monitor the deflection (measure with a laser, alarm at >25mm): because progressive sagging raises the stress and early awareness helps, the deflection is monitored;
6) Perform a bearing test (hydrostatic test to check the deflection): because the original lack of testing left the sag undiscovered, the test confirms compliance, so bearing is tested;
7) Control the temperature against expansion sag (cold insulation reduces thermal change): because expansion sags and control relieves it, the temperature is controlled;
8) Write the span calculation and added supports into the calculation sheet: the original design omission was the root cause of the span, so calculation controls the design and no sagging occurs.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping