MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Restraint Support Failure

Restraint Support Failure

E44-800 · Piping Supports and Thermal Expansion · Restraint Support · ★★

Problem Description

Restraint failed, pipe shifted >15mm, pushing the equipment

Root Cause

[Mechanism] Failure of the restraint anchorage lets the pipe shift.
[Calculation] The failed restraint lets the pipe displacement >15mm and push the equipment nozzle.
[Design Omission] Neither securing nor a force check was provided — so it must be secured.

Corrective Solution

1) Re-secure the restraint support (weld the anchor plate firmly / chemical anchors): because the original failed restraint let the pipe shift >15mm and push the equipment nozzle, securing the restraint stabilizes the pipe;
2) Check the restraint force against the thrust (design the anchoring force ≥1.5 times the blind-flange force + thermal thrust): because a weak restraint shifts and the check ensures adequacy, the force is checked;
3) Weld the anchorage firmly (double-sided weld, leg ≥6mm): because looseness shifts and welding secures it, it is welded;
4) Add a thrust-restraint pier (a concrete pier carries the thrust): because thrust shifts the pipe and the pier stops it, thrust is stopped;
5) Monitor the restraint condition (displacement-mark monitoring, alarm at >5mm): because progressive failure cracks the equipment nozzle and early awareness helps, the restraint is monitored;
6) Perform a thrust test (pressurize and record the restraint displacement): because the original lack of testing left the failure undiscovered, the test reveals the bearing capacity, so thrust is tested;
7) Control the thermal displacement (provide compensation on the adjacent section to absorb the thrust): because expansion pushes and compensation relieves it, the displacement is controlled;
8) Write the restraint securing and welding into the assembly card: the original lack of securing was the root cause of the failure, so assembly controls the work and the restraint is stable.

Checklist

Reference

GB/T 17116.1-2018 Pipe supports and hangers

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL