Undersized suction pipe on the pump gives a high velocity and causes cavitation

E44-204 · Pump Selection & Cavitation · Horizontal Centrifugal Pump IS100-65-250 · ★★★

Problem Symptom

The suction pipe was DN65 (DN100 should have been used) and the suction velocity reached 3.8m/s against a design limit of 1.5m/s, the inlet vacuum was -0.04MPa and cavitation noise was present

Root Cause

[Cavitation] The small diameter and high velocity increase the friction and local losses sharply and consume the available NPSH.
[Calculation] hf=lambda*L/d*v2/2g; raising v from 1.5 to 3.8 increases v2 by a factor of 6.4 and lifts hf from 0.5 to 3.2m, leaving NPSHa=2.0m against NPSHr of 2.8m.
[Design Omission] The suction pipe was sized from the discharge pipe and was not independently selected for low velocity, so cavitation occurred.

Correct Solution

1) Enlarge the suction pipe to DN100 so the velocity is 1.5m/s maximum: as the velocity falls v2 falls and hf falls, so hf drops from 3.2m to 0.5m and NPSHa recovers;
2) Make the suction pipe one to two sizes larger than the discharge pipe: the suction side is sensitive to pressure drop, so a low velocity is preserved;
3) Shorten the suction pipe to reduce the friction loss: hf varies with L, so halving the length halves hf;
4) Minimise elbows and valves in the suction pipe to cut the local losses: each elbow contributes about 0.3, so the local hf falls;
5) Use large-radius elbows in the suction pipe: a large R/d ratio gives a small zeta, so the loss is reduced;
6) Re-check that NPSHa is at least NPSHr+0.5: an insufficient margin makes cavitation easy, so a safety boundary is retained;
7) Commission the pump and verify the suction velocity and the inlet pressure meet the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the independent selection of the suction pipe diameter in the design: sizing it from the discharge pipe was the root cause, so the design must always include it.

Checklist

References

GB/T 13006-2013 Centrifugal Pumps - NPSH