E44-205 · Pump Selection & Cavitation · Inline Centrifugal Pump ISG80-160 · ★★
The suction pipe had 4 elbows of 90 degrees against a design limit of 1, the local loss was 1.8m, NPSHa of 2.1m fell below NPSHr of 2.6m and slight cavitation occurred
[Cavitation] The many elbows stack up the local losses and the total suction-side loss consumes too much of the available NPSH.
[Calculation] hj=the sum of zeta*v2/2g; the 4 elbows contribute 1.2 in total and at 1.5m/s hj=0.14m, accumulating with the inlet to 1.8m, so NPSHa is insufficient.
[Design Omission] The suction pipe layout used too many elbows and the routing was never optimised, so cavitation occurred.
1) Optimise the suction pipe routing to reduce it to 1 elbow maximum: fewer elbows give a smaller sum of zeta, so hj drops from 1.8 to 0.5m;
2) Where a turn is unavoidable, use large-radius elbows (R of at least 1.5d): a large radius gives a small zeta, so the single elbow zeta falls from 0.3 to 0.15;
3) Keep at least 5d of straight pipe between elbows: elbows too close together make the flow pattern degrade, so the flow is stabilised;
4) Leave at least 5d of straight pipe ahead of the pump inlet: the inlet flow pattern affects cavitation, so the approach flow is made uniform;
5) Avoid local high points in the suction pipe that trap gas: a gas pocket reduces the effective flow area, so gas locking is prevented;
6) Re-check the NPSHa margin at 0.5m or more: an insufficient margin leaves no safety boundary, so it is retained;
7) Commission the pump and verify the inlet pressure and NPSHa meet the design values: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the suction pipe layout rules in the design: too many elbows was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH