E44-206 · Pump Selection & Cavitation · Variable-Speed Centrifugal Pump IS125-100-200 · ★★★
The variable-speed drive was run up to 55Hz against a rated 50Hz, so the speed exceeded rating by 10%, NPSHr rose from 3.0 to 3.6m against NPSHa of 3.2m, and the impeller cavitated
[Cavitation] The higher speed raises NPSHr in proportion to n squared until it exceeds NPSHa.
[Calculation] NPSHr varies as n squared, so a 10% speed rise raises NPSHr by about 21%, from 3.0 to 3.6m against NPSHa of 3.2m, and the bubbles collapse.
[Design Omission] The variable-speed upper limit was never constrained by the available NPSHa and there was no over-frequency protection, so cavitation occurred.
1) Limit the variable-speed upper limit to 50Hz: at over-frequency NPSHr rises as n squared and jumps up, so NPSHr never exceeds NPSHa;
2) Back-calculate the permissible maximum speed from NPSHa: the limit is reached when NPSHr equals NPSHa, so a safe upper limit is set this way;
3) Increase the suction submergence for the high-speed duty: greater submergence raises NPSHa and compensates for the rising NPSHr;
4) Fit a hard frequency upper limit in the drive: operator error can cause over-frequency, so this prevents the limit being exceeded;
5) Select a pump with a lower base NPSHr to retain an over-frequency margin: a larger margin keeps the machine safe even above rated frequency;
6) Monitor the inlet pressure and interlock to reduce the frequency: the precursor of cavitation is the inlet vacuum, so this protects the machine in time;
7) Commission the pump at the highest frequency and verify there is no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the variable-speed upper limit constraint in the selection report: the original absence of the constraint was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH