Pumping hot water at a raised vapour pressure causes cavitation

E44-207 · Pump Selection & Cavitation · Hot Water Circulation Pump IRG65-160 · ★★★

Problem Symptom

The medium at 95 degrees Celsius (the design was based on 60 degrees Celsius) raised Pv from 0.02 to 0.085MPa, dropping NPSHa from 4.0 to 1.5m against NPSHr of 2.5m, so cavitation occurred

Root Cause

[Cavitation] The temperature rise increases the vapour pressure Pv sharply, so the Pv/rho*g term subtracted in NPSHa becomes much larger.
[Calculation] NPSHa=Pa/rho*g-Hs-hf-Pv/rho*g; raising Pv from 0.02 to 0.085MPa increases the last term by 6.5m and NPSHa collapses from 4.0 to 1.5m.
[Design Omission] Pv was taken at the low temperature during selection and not at the actual maximum water temperature, so cavitation occurred.

Correct Solution

1) Recalculate NPSHa with Pv=0.085MPa taken at the actual maximum water temperature of 95 degrees Celsius: Pv rises steeply with temperature, so the design value becomes realistic;
2) Increase the suction submergence to compensate for the NPSHa loss: greater submergence raises NPSHa and offsets the increase in Pv;
3) Add back pressure on the suction side (raise the expansion tank): a higher static pressure raises NPSHa and makes up the difference;
4) Select a pump type with a lower NPSHr: the margin is tight in high-temperature duty, so a safety boundary is retained;
5) Insulate the suction line to stop the medium heating further: any temperature rise increases Pv again, so the temperature is controlled;
6) Review the case of the highest water temperature of the year: summer conditions are the most severe, so the machine is safe over the whole range;
7) Commission the pump at the highest water temperature and verify there is no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the maximum medium temperature in the cavitation check: the original use of the low temperature was the root cause, so the design must always include it.