E44-872 · Throttling Noise and Vibration · Valve stem · ★★★
The slender valve stem's natural frequency approached the flow pulsation frequency, risking stem vibration and breakage
[Mechanism] The slender valve stem's natural frequency approaches the fluid pulsation frequency; the fluid-structure coupled resonance amplifies the amplitude and risks stem breakage.
[Calculation] Stem natural frequency fn=(π/2L)²√(EI/μ); near the pulsation frequency Q is amplified so the stress exceeds yield.
[Design Omission] No stem-frequency verification, no thickening, no damping.
1) Verify the stem natural frequency (change the diameter or supports so fn deviates from the flow pulsation frequency by ≥30%), since the original fn near the pulsation frequency amplified resonance, thus verifying the frequency avoids vibration;
2) Thicken the valve stem (diameter from 20mm to 28mm for stiffness), since slender causes vibration and thick is rigid, thus thickening;
3) Add a damping pad (damping in the actuator), since oscillation causes vibration and damping suppresses it, thus damping;
4) Use a shorter overhang (shorten the exposed stem length), since long vibrates and short is stable, thus shortening;
5) Monitor the vibration (measure the stem amplitude, alarm >0.2mm), since gradual vibration approaches breakage and early detection catches it, thus monitoring vibration;
6) Run a vibration test (excite and measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the resonance peak, thus testing vibration;
7) Control the flow to steady the speed (limit v to reduce pulsation), since changing conditions drift the frequency near the natural one and steadying moves it away, thus controlling speed;
8) Write the frequency verification and thickening into the calculation sheet, since the original lack of verification is the root cause of vibration and locking it in closes the loop, thus controlling it in the calculation.
GB/T 12224-2015 Steel valves - General requirements