E44-836 · Piping Supports and Thermal Expansion · Equipment Nozzle · ★★★
Nozzle additional load > allowable, cracking, leakage
[Mechanism] Thermal expansion of the pipe pushes the equipment nozzle, producing a large additional load.
[Calculation] The additional load exceeds the equipment allowable, and the nozzle cracks and leaks.
[Design Omission] Neither compensation nor restraint was provided — so both must be added.
1) Install compensation to reduce the additional load (axial expansion joints absorb the thermal growth): because the original load exceeded the equipment allowable and cracked and leaked the nozzle, compensation reduces the load;
2) Check the nozzle load ≤ allowable (per equipment data, ≤ allowable × 0.5): because exceeding it cracks the nozzle, the check is made;
3) Add an anchor pier to carry the thrust (the pier carries the blind-flange force + thermal thrust): because the thrust cracks the nozzle and the pier stops it, the thrust is carried;
4) Leave expansion clearance at the nozzle (provide an expansion gap on the nozzle side): because without it the load rises and the gap relieves it, the clearance is provided;
5) Monitor the load condition (load cells / displacement monitoring, with alarms): because the load grows gradually and cracks the nozzle and early awareness helps, the load is monitored;
6) Perform a hot test (raise the temperature and record the forces at the equipment nozzle): because the original lack of testing left the force undiscovered, the test identifies the load points, so the hot test is run;
7) Control thermal displacement (use flexible connections): because expansion produces the load and flexibility absorbs it, displacement is controlled;
8) Write the compensation and load check into the calculation sheet: the original lack of compensation was the root cause of the load, so calculation controls the design and the nozzle does not crack.
GB/T 20801.3-2020 Design code for industrial metallic piping