E44-087 · Throttling Noise and Vibration · Control Valve · ★★
Long-term throttling by the control valve at small opening keeps the velocity high; the whistling noise of 95dB(A) exceeds 85 and fails the environmental limit
[Whistling] At small opening the contracted flow makes the local velocity excessive and separates the boundary layer, causing the whistle.
[Calculation] An opening <10% makes the contracted-flow velocity excessive, giving 95dB noise.
[Design Omission] No suitable KV was selected and the small opening was not avoided — hence the whistle.
1) Select a valve with a suitable KV to avoid small opening: because a wrong KV puts the operating point below 10% opening and a correct KV keeps it in the mid-range, the contracted-flow whistle is avoided;
2) Move the operating point away from <10% opening (re-specify the control valve or split range with a bypass): because the contracted-flow velocity at small opening causes the whistle and moving away lowers v, the noise drops;
3) Switch to a low-noise valve type (e.g., multi-stage pressure reduction or a noise-reducing trim): because a low-noise valve stages the pressure drop and avoids single-point high velocity, the noise drops at the source;
4) Modestly enlarge the downstream diameter to reduce velocity: because enlarging lowers v and the noise falls with v², the noise is further reduced;
5) Add a silencer (reactive / resistive, downstream): because the silencer absorbs the specific frequency band and lowers the sound pressure, the target ≤85 is met;
6) Enclose the valve set in a sound hood: because the hood blocks transmission and lowers the ambient noise, the environmental limit is met;
7) Measure noise ≤85dB(A) at commissioning: because 95dB exceeds 85 and must be verified by measurement, compliance is confirmed;
8) Include noise in the selection specification: the original failure to avoid small opening caused the whistle, so noise must be checked at the selection stage.
GB/T 17213-2015 Industrial-process control valves