E44-088 · Throttling Noise and Vibration · Throttling Orifice Plate · ★★
Vortex shedding after the orifice plate produces 88dB noise and vibrates the pipe section, loosening the support bolts
[Vortex] The sudden enlargement after the orifice plate forms a Karman vortex street, inducing vibration and noise.
[Calculation] The vortex frequency f=St·v/d approaches the pipe natural frequency, causing 88dB resonance noise.
[Design Omission] No downstream straight run and no resonance avoidance — the vortex caused vibration.
1) Keep enough straight pipe downstream (≥10D): because a short run lets the vortex strike before it decays, sufficient length stabilizes the flow field and reduces vortex-induced vibration;
2) Avoid the vortex frequency nearing the natural frequency (adjust spacing or diameter): because when f=St·v/d approaches the pipe natural frequency it resonates; staggering them prevents vibration and eliminates resonance;
3) Add supports and damping (clamps + damper): because supports raise the natural frequency and damping dissipates energy, vibration is suppressed and the bolts stay tight;
4) Select a low-noise orifice plate (e.g., multi-hole or balanced): because it splits the flow and reduces downstream vortices, the noise and vibration drop;
5) Sound-insulate the pipe section: because insulation blocks transmission and lowers the ambient level, the target is met;
6) Check the natural frequency (keep ≥20% apart from the vortex frequency): because resonance is the root cause and a check predicts it, design control is achieved;
7) Measure vibration and noise at commissioning (vibration velocity + sound pressure): because vibration and noise are the outcome and must be measured, giving acceptance;
8) Include vortex-induced vibration in layout practice: the original lack of a straight run caused the vortex-induced vibration, so it must be controlled at the layout stage.
GB/T 2624-2006 Orifice-plate flowmeters