Centrifugal Pump Cavitation Noise and Vibration

E44-089 · Throttling Noise and Vibration · Centrifugal Pump · ★★

Problem Description

Pump cavitation produces 92dB noise with erosion pits at the impeller inlet; the vibration velocity of 7mm/s exceeds 4.5

Root Cause

[Cavitation Noise] Bubble-collapse impacts produce broadband noise of 92dB.
[Calculation] Cavitation raises the noise about 20dB above normal, accompanied by vibration.
[Design Omission] Insufficient NPSHa causes cavitation, showing up as noise and vibration.

Corrective Solution

1) Raise the NPSHa to ≥NPSHr+0.5m: because insufficient NPSHa causes cavitation and extra margin eliminates bubble collapse, the noise and vibration drop;
2) Select a cavitation-resistant impeller (e.g., inducer or double-suction): because such an impeller tolerates vapor-laden conditions and reduces collapse impact, the vibration and noise decrease;
3) Reduce the speed or add an inducer: because lower speed reduces NPSHr and the inducer pre-swirl raises the inlet pressure, cavitation is eliminated;
4) Install a filter at the inlet to reduce resistance: because blockage increases the inlet loss and lowers the NPSHa, filtering preserves the margin and prevents cavitation recurrence;
5) Monitor noise and vibration (online vibration velocity + sound level): because 92dB / 7mm/s exceeds 4.5 and must be watched, early detection allows timely action;
6) Inspect the impeller periodically (looking for erosion pits): because cavitation damages the impeller, periodic inspection prevents perforation and extends life;
7) Measure noise and vibration at commissioning (≤85dB, ≤4.5mm/s): because cavitation shows up as noise and vibration, it must be measured, giving acceptance;
8) Include cavitation protection in selection: the original insufficient NPSHa caused cavitation, so the margin must be checked at the selection stage.

Checklist

Reference

GB/T 13006-2013 Centrifugal pumps — Efficiency

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »