Surge Noise from Too-Rapid Diffusion Downstream of the Pressure-Reducing Valve

E44-139 · Throttling Noise and Vibration · Steam Pressure-Reducing Valve · ★★

Problem Description

Straight diffusion after pressure reduction makes the velocity change abruptly; the surge noise reaches 92dB and the seat cracks

Root Cause

[Too-Rapid Diffusion] A sudden expansion of the cross-section drops the velocity sharply and the pressure rebounds, causing surge.
[Noise] The turbulent-pulsation sound power ∝ Δp.
[Design Omission] No gradual expansion and no pressure-drop control — the surge caused cracking.

Corrective Solution

1) Provide a gradual diffuser after reduction, limiting the diffusion angle ≤7°: because sudden expansion drops the velocity and surges, gradual expansion stabilizes the flow;
2) Use staged reduction, limiting the single-stage pressure-drop ratio ≤0.5: because a large drop causes turbulent noise, staging reduces the noise;
3) Install a silencer downstream: because the pulsation sound is strong, silencing cuts the dB;
4) Keep a straight pipe run ≥10D after the valve: because a short run leaves the vortices disordered, a long straight run stabilizes them;
5) Select a low-noise reducing trim: because the trim type affects noise, a low-noise trim is chosen;
6) Densify and damp the supports against transmitted vibration: because vibration cracks the seat, damping stops the cracking;
7) Measure noise ≤85dB(A) at commissioning: the design requirement must be verified by measurement, confirming delivery;
8) Include diffusion and silencing in the downstream design: the original sudden expansion was the root cause of the surge, so it must be included in design.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves