E44-039 · Throttling Noise and Vibration · Reciprocating Compressor Discharge Pipe · ★★★
Gas pulsation vibrates the piping with 3mm amplitude, leaks the flange and cracks the foundation
[Pulsation] Reciprocating compression generates a pressure pulsation Δp that couples with the pipe natural frequency and is amplified.
[Resonance] The pulsation energy is transmitted through the supports into the building.
[Design Omission] No buffer tank / orifice plate and no pulsation-spectrum analysis — the pulsation caused vibration.
1) Install a buffer tank at the discharge to attenuate the pulsation: because the buffer volume clips the peak and lowers Δp, the tank damps the pulsation;
2) Add a throttling orifice plate to shift the pulsation spectrum and avoid resonance: because the plate changes the pulsation frequency and staggers it from the natural frequency, spectrum tuning avoids vibration;
3) Stagger the piping natural frequency from the pulsation frequency: because coupling amplifies it to 3mm amplitude, the frequencies are staggered;
4) Add dampers to the supports to absorb energy: because damping dissipates the pulsation energy and reduces transmission to the building, energy is absorbed;
5) Reinforce the flange for the pulsation load: because pulsation fatigues and leaks the flange, reinforcement is applied;
6) Perform a pulsation-spectrum analysis to establish safety: because the analysis quantifies the safety margin, the design follows the spectrum;
7) Measure vibration ≤0.1mm at commissioning (originally 3mm): because meeting the vibration target means decoupling, acceptance is granted;
8) Include pulsation control in the piping design: the original lack of a buffer was the root cause of the pulsation, so it must be included in design.
GB/T 25359-2018 Petroleum and natural gas industries - Compressor specifications