Knowledge Base › Fluid Systems Error Case › Vortex Noise after the Orifice Plate, Pipe Vibration and Support Loosening

Vortex Noise after the Orifice Plate, Pipe Vibration and Support Loosening

E44-038 · Throttling Noise and Vibration · Steam Orifice-Plate Flowmeter · ★★

Problem Description

Vortex noise of 88dB downstream of the orifice plate, pipe vibration and support loosening

Root Cause

[Vortex] The turbulent vortex-shedding frequency f=St·v/d after the orifice plate falls on the piping natural frequency and triggers resonance.
[Sound Power] Lw ∝ Δp·Q, which rises.
[Design Omission] No downstream straight run ≥10D and no vortex elimination — the vortex noise caused vibration.

Corrective Solution

1) Keep a straight pipe run ≥10D downstream of the orifice plate: because a short run lets the vortices persist and induce vibration, a long straight run stabilizes the flow and eliminates the vortices;
2) Keep the piping natural frequency away from the vortex frequency: because when f=St·v/d falls on the natural frequency it resonates, staggering avoids vibration;
3) Add a vortex-breaking grid or flow straightener: because the grid breaks the vortices and the straightener stabilizes the flow, the vortices are eliminated;
4) Densify the supports and add damping: because damping absorbs vibration energy and the supports hold the pipe, vibration is suppressed;
5) Provide sound insulation where noise exceeds 85dB: because 88 exceeds the environmental limit, insulation is used;
6) Keep the velocity within a reasonable range: because a high velocity raises the vortex frequency and makes resonance likely, the velocity is controlled;
7) Measure noise and vibration at commissioning: because measurement confirms no resonance, acceptance is granted;
8) Include the straight run in the flowmeter layout: the original failure to leave 10D was the root cause of the vortex vibration, so it must be provided in the layout.

Checklist

Reference

GB/T 2624-2016 Orifice-plate flowmeters