E44-230 · Pump Selection & Cavitation · Condensate Pump NLT150-400 · ★★★
The condensate was in a saturated state (Pv equals the saturation pressure at the current temperature), leaving only NPSHa of 0.8m against NPSHr of 1.5m, and cavitation was frequent
[Cavitation] In saturated condensate the vapour pressure equals the current pressure, so any pressure drop causes vaporisation and cavitation is very likely.
[Calculation] For saturated water Pa is approximately Pv and NPSHa=Hz-hf is about 0.8m against NPSHr of 1.5m, so a slight pressure drop causes flash evaporation and cavitation.
[Design Omission] The hotwell was not raised nor a low NPSHr condensate pump selected specifically for saturated water, so cavitation occurred.
1) Raise the hotwell or condenser liquid level to increase the static pressure: saturated water relies on the elevation difference to provide NPSHa, so this makes up the difference;
2) Select a condensate pump with an ultra-low NPSHr for saturated duty (vertical can type): the NPSHr of such a pump is very low, so it suits saturated water;
3) Fit an inducer on the first stage to lower NPSHr: the inducer raises the inlet pressure, so the margin grows;
4) Keep the suction pipe short and large-bore to minimise hf: saturated water tolerates no pressure drop, so the loss is reduced;
5) Control the hotwell level steadily to prevent fluctuation: level fluctuation causes cavitation, so the pressure is stabilised;
6) Install inlet pressure monitoring with an interlock: it is the precursor of cavitation, so this protects the machine;
7) Commission the pump and measure the hotwell level and the inlet pressure, confirming no cavitation: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include a dedicated saturated water design in the procedure: the original lack of a dedicated design was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH