E44-229 · Pump Selection & Cavitation · Mismatched Centrifugal Pump IS100-65-200 · ★★★
The selected pump had NPSHr of 3.4m and the site NPSHa was 3.6m, so the margin was only 0.2m against the 0.5m required and any process fluctuation caused cavitation
[Cavitation] The selection left insufficient cavitation margin, so a slight process disturbance brings NPSHa below NPSHr and cavitation occurs.
[Calculation] The requirement is NPSHa at least NPSHr+0.5, but the actual margin was 0.2m, so any increase in flow or water temperature pushes the duty past the limit and cavitation follows.
[Design Omission] The selection did not apply the safety rule NPSHa at least NPSHr+0.5, so the margin was insufficient.
1) Reselect a pump type with a lower NPSHr so the margin is 0.5m or more: the margin absorbs process fluctuations, so the limit is not exceeded;
2) Fit an inducer to lower the NPSHr of the existing pump: the inducer raises the inlet pressure, so NPSHr falls and the margin grows;
3) Increase the suction submergence to lift NPSHa: greater submergence raises NPSHa, so the margin grows;
4) Shorten the suction pipe and reduce its losses: hf consumes NPSHa, so NPSHa rises;
5) Check the margin against the most severe combination (high temperature and high flow): the severe point is the most tightly constrained, so the machine is safe over the whole range;
6) Install inlet pressure monitoring as a cavitation warning: a small margin makes cavitation easy, so this protects the machine;
7) Commission the pump and verify the margin between NPSHa and NPSHr meets the requirement: the design requirement must be verified by measurement, so this confirms the delivery;
8) Include the margin rule in the selection report: the original failure to leave a margin was the root cause, so the design must always include it.
GB/T 13006-2013 Centrifugal Pumps - NPSH