E44-1024 · Excessive Piping Resistance & Pressure Drop · Piping · ★★
Many elbows, high resistance, large pressure drop
[Mechanism] Too many bends in the pipework accumulate local resistance coefficients, and the total pressure drop exceeds the design.
[Calculation] Originally 12 x 90 degrees elbows (xi=0.75 each) and 2 tees (xi=1.5), so Sum_xi=12x0.75+2x1.5=12 and the local hf=Sum_xi*v^2/2g=12x1.8^2/19.6=1.99m, which is 55% of the total resistance.
[Design Omission] The pipe routing was never optimised, the local resistance was never verified, and the elbow count was never reduced.
1) Optimise the routing down to 6 elbows (merge the directions, use 45 degrees instead of 90 degrees); the original 12 elbows gave Sum_xi=12 and a local hf=1.99m, 55% of the total resistance, so halving them lowers the resistance and the total drops 40%;
2) Verify the local resistance Sum_xi*v^2/2g<=0.5m (using the xi tables); the accumulated xi causes the pressure drop and the check quantifies it;
3) Change to a larger bend radius R>=1.5d (xi falls from 0.75 to 0.35); sharp bends give a large xi and changing the radius lowers it, reducing the resistance;
4) Use a flow-through tee instead of a right-angle branch (xi falls from 1.5 to 0.3); a right-angle branch gives a large xi while a straight-through tee lowers it, reducing the resistance;
5) Carry out a resistance test (measure the actual DeltaP distribution); without the test the real xi values are unknown, so measurement validates them and the data fixes the resistance;
6) Raise the pump head with a 15% margin; a large local resistance leaves the terminal under-pressurised and raising the head compensates, securing the flow;
7) Control the flow at or below design (above that v^2 raises the resistance); excess raises hf and controlling it slows the rise, keeping the resistance steady in operation;
8) Write the optimised routing and the xi verification into the calculation sheet; the root cause of the elbow excess was a routing that was never optimised with no Sum_xi check, so the calculation sheet closes the loop.
GB/T 20801.3-2020 Design Code for Industrial Metallic Piping