E44-393 · Water Hammer and Pressure Surge · Expansion Joint Pulled Apart · ★★
Alternating tension/compression from the hammer defeats the joint's travel limit, causing it to dislodge, spray the medium, and shut down the line.
[Alternating Loading] The hammer imposes alternating tension/compression beyond the travel limit, dislodging the joint.
[Jetting] Dislodgement sprays the medium and shuts down the line.
[Design Omission] No travel limit and no anchoring were provided for the expansion joint — it dislodged.
1) Provide bi-directional travel stops and anchoring for the joint: alternating loading exceeded the limit, dislodging and spraying; stops and anchoring secure it;
2) Check hammer displacement ≤ joint allowable: exceeding it dislodges, so displacement is calculated;
3) Add supports on both sides of the joint to resist tension: tension caused dislodgement, so tie rods are used;
4) Install an arrester to cut the amplitude: the wave amplitude is large, so it absorbs the peak;
5) Slow-closing check valves reduce alternating loading: a large source makes strong cycles, so slow closing is used;
6) Periodically inspect travel stops for looseness: looseness causes dislodgement, so stops are inspected;
7) Verify displacement by water-hammer simulation: estimates fall short, so simulation is used;
8) Write expansion-joint protection into the design: the original lack of limits was the root cause of dislodgement, so design review enforces it.
GB/T 32284-2015 Code for design of pump stations - Water hammer protection