E44-557 · Seal Leakage · Mechanical Seal Flush Line · ★★
The chamber temperature hit 95℃, over the 70℃ limit; flush flow was 0 and leak was 1L/h.
[Mechanism] A blocked flush line leaves the faces unlubricated and they heat up.
[Calculation] Zero flow makes temperature 95 >70℃, the film breaks and leaks.
[Design Omission] No filtration, no flow monitoring, and no line routing — blockage.
1) Add a flush strainer (100-mesh Y-type); blockage leaves no lubrication, and weld slag and scale are the blockage source, so filter debris to protect flow and hold 1L/min;
2) Open a flush bypass to hold 1L/min flow; the main line blocks and cuts flow while the bypass keeps continuous flush, so the bypass holds flow and cools;
3) Monitor flush flow and alarm (warn at ≤0.5L/min); blockage drives flow to 0 before the temperature rises, so monitor flow and warn;
4) Hold chamber temperature ≤70℃ (thermocouple interlock); when >70 the liquid film vaporizes, breaks, and leaks, so cool to hold the film;
5) Clear the flush line against blockage (periodic blow-through); blockage causes temperature rise, so clear the line to restore flow;
6) Choose self-flush Plan 11 (taken from pump discharge); an external source blocks easily while self-flush is steady, so self-flush is reliable;
7) Periodically check flow (every shift); blockage gradually reduces flow, so check flow against cutoff;
8) Write flush filtration into the spec; the missing filtration was the blockage root cause, so gate the spec.
GB/T 14211-2019 Mechanical seals - Specifications