Increased roughness in a long pipeline raises the friction loss and the pressure drop

E44-054 · Excessive Piping Resistance & Pressure Drop · Long distance water transmission pipe · ★★

Problem Symptom

After 2km of operation the pipe wall roughness made the actual pressure drop about 176kPa against a design value of 130kPa, 35% higher, so the pressure at the end was insufficient and the equipment supply was unstable

Root Cause

[Friction Loss] hf=λL/d·v²/2g, and an increase in roughness Δ raises λ.
[Calculation] The roughness increase lifts λ from 0.018 to 0.025, so hf rises from 13m of water column to 18m (about 176kPa), an increase of 38% that exceeds the design value.
[Design Omission] No resistance margin was allowed and the pump was not selected on the actual roughness, so the pressure at the end was insufficient.

Correct Solution

1) Pig the line to restore the internal wall roughness to the design value (returning Δ from the as-operated value to the design value), because a lower roughness Δ brings the friction coefficient λ back from 0.025 to 0.018 and the friction loss hf=λL/d·v²/2g falls accordingly, so hf drops from 18m of water column to 13m (about 130kPa) and the end pressure returns to the design value;
2) Enlarge the undersized pipe sections to the design diameter and lower the velocity, because hf∝v² and a lower v reduces the friction loss quadratically, thereby raising the end pressure and cutting energy use at the same flow rate;
3) Raise the pump head or change the pump type to make up the resistance margin, because the original pump was selected on the design 130kPa with no roughness allowance and actually saw 176kPa, thereby making up the pressure drop with head so the end supply stays stable;
4) Install a booster station midway along the 2km line, because the pressure drop over a single long run accumulates beyond the rating and leaves the end short of pressure, thereby pressurising each segment so that each drop stays within the design value and the end pressure is guaranteed;
5) Control the design velocity within 1.5 to 2m/s, because λ is low in that band with low energy use and controllable pressure drop, thereby avoiding high velocity and large drops at the source;
6) Install pressure measurement points along the line (one every 500m), because the drop in a long line changes gradually and a single point cannot reveal a local anomaly, thereby monitoring the pressure drop distribution in real time and detecting blockages or rough sections early;
7) Measure the end pressure during commissioning and check the actual hf against the design, because the design value is based on an ideal roughness and the actual must be verified by measurement, thereby confirming whether the margin is genuinely sufficient;
8) Include the roughness design allowance (take 1.2 times the upper limit of λ) in the hydraulic calculation, because scaling and roughness necessarily increase in service and any omission leaves the end short of pressure, thereby reserving the margin at the selection stage and preventing recurrence.

Checklist

References

GB/T 20801-2020 Pressure Piping Code

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »