E44-1096 · Other · Atomizing Spray Gun · ★★
Blocked, mist, coarse.
[Mechanism] The gun feed carried solids and air pressure was low; atomized droplets were coarse and coverage uneven, giving poor humidification/coating quality.
[Calculation] Air supply 0.3MPa (should be ≥0.5); atomized droplet size d50=120μm (should be ≤50); coverage uniformity only 65%.
[Design Omission] No filtration, no air-pressure control, no bore check, and no mist test.
1) Add filtration (100μm) against blockage; solids block, and filtering cleans it, making the mist fine;
2) Control air pressure ≥0.5MPa (add makeup to stabilize); low pressure makes it coarse, and adequate pressure makes the mist even;
3) Check the spray hole Φ1.5mm (replacing Φ2.5); a large hole is coarse, and a small bore makes the mist fine;
4) Provide clearing (daily back-blow); deposition blocks, and clearing opens it, restoring evenness;
5) Run a mist test (d50≤50μm, coverage ≥90%); untested means unknown, and measured fineness confirms it;
6) Install droplet-size monitoring (alarm on coarseness); a blockage first shows as droplet-size rise, and early warning catches it;
7) Set a cleaning interval (daily); long intervals block, and controlled intervals keep it clean, preventing blockage;
8) Record filtration and pressure control on the gun drawing; the root cause of coarseness was no filtration and low pressure, so the drawing must gate it.
GB/T 10895-2008 Cooling