Knowledge Base › Fluid Systems Error Case › Pressure-Reducing Valve High-Frequency Howling

Pressure-Reducing Valve High-Frequency Howling

E44-842 · Throttling Noise and Vibration · Pressure-reducing valve · ★★

Problem Description

A DN80 pressure-reducing valve with a 1.6MPa inlet and a 0.3MPa outlet howled at about 2100Hz with a sound pressure level of 92dB(A)

Root Cause

[Mechanism] The jet vortex-shedding frequency behind the valve disc approaches the valve body's natural frequency, and the fluid-structure coupling triggers high-frequency self-excited howling.
[Calculation] Vortex shedding f=St·v/d=0.2×45/0.0043≈2093Hz, coinciding with the valve body's natural frequency of 2100Hz; Strouhal number 0.2.
[Design Omission] No check of vortex-versus-natural-frequency separation, no silencer fitted, no frequency test.

Corrective Solution

1) Frequency-avoidance design (change the seat throat diameter so f deviates from the natural frequency by ≥20%, i.e. <1680Hz or >2520Hz), since the original 2093Hz coincided with 2100Hz and howled, thus detuning stops the howl;
2) Verify the frequency separation (at least 20% between the vortex frequency and the natural frequency), since closeness howls and verification avoids it, thus verifying the separation;
3) Add a baffle-type silencer (insertion loss ≥12dB), since the bare valve radiated 92dB(A) and silencing lowers it, thus silencing;
4) Adjust the pressure-reducing stages (two-stage reduction to cut the single-stage drop), since a single steep drop raises the velocity and howls and adjusting eases it, thus adjusting the stages;
5) Inspect for howling (a spectrum analyzer to measure the peak frequency, alarm when the peak exceeds 85dB(A)), since gradual growth approaches howling and early detection catches it, thus inspecting for howling;
6) Run a frequency test (sweep the frequency and measure the response peak), since the lack of testing left the howling undetected and the test reveals the resonance peak, thus frequency testing;
7) Control outlet stability (a surge tank to damp flow fluctuation), since fluctuation drifts the frequency toward the natural frequency and stabilizing keeps it away, thus controlling stability;
8) Write the detuning and silencing into the specification, since the original omission is the root cause of howling and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 17213.1-2015 Industrial-process control valves