E44-692 · Hydraulic System Contamination and Crawling · Hydraulic Systems · ★★
Low pressure, weak output
[Mechanism] The system pressure is too low to drive the actuators.
[Calculation] Internal leakage drops the system pressure.
[Design Omission] No leak search, no calibration, and no inspection - the root cause of leakage.
1) Hunt down the leaks and reseal (pressure-hold leak search, replace seals); system pressure originally dropped from 16 to 11MPa, leaving actuators weak, so finding and fixing leaks restores pressure;
2) Calibrate pump displacement (adjust the variable pump to rated stroke); insufficient displacement lowers pressure, and calibration restores full delivery;
3) Clean the stuck relief valve (teardown flush); a stuck-open relief valve leaks off pressure, and cleaning lets it seat, holding the pressure;
4) Raise the pump pressure setting (to the rated 16MPa); a low setting caused the weak output, and raising it restores adequate pressure;
5) Check internal leakage (pressure-hold test, decay ≤0.5MPa/5min); internal leakage lowers pressure, and the test quantifies it;
6) Keep the oil clean to prevent sticking (NAS 9); sticking causes leakage, and cleanliness control prevents it, reducing sticking;
7) Check pressure on a fixed schedule (each shift, gauge calibrated); gradual pressure loss is invisible, and checking catches it, giving early warning;
8) Write leak search and pressure calibration into the maintenance card (pressure-hold records); the original failure to hunt leaks was the root cause, so closing the loop in maintenance serves as the gate.
GB/T 3766-2015 General technical conditions for hydraulic systems