E44-693 · Hydraulic System Contamination and Crawling · Actuators · ★★
Weak output, sluggish motion
[Mechanism] Low system pressure leaves actuators weak.
[Calculation] Low pressure produces low actuator force.
[Design Omission] No pressure raising, no leak search, and no inspection - the root cause of low pressure.
1) Raise the system pressure (to the rated 16MPa); low pressure originally left the output force at only 70% of rated with sluggish motion, so raising the pressure restores the force;
2) Check the cylinder for internal leakage (pressure hold, replace seals); internal leakage weakens the actuator, and finding and fixing it restores the force;
3) Calibrate the relief valve setting (to rated); a low setting caused the weak output, and calibration restores full pressure;
4) Clean stuck valves (teardown flush); sticking lowers pressure, and cleaning restores flow;
5) Check actuator effectiveness (force sensor, alarm at deviation >10%); output decay weakens the actuator, and checking catches it, giving early warning;
6) Keep the oil clean (NAS 9); sticking lowers pressure, and cleanliness control prevents it, reducing sticking;
7) Check force on a fixed schedule (each shift, recorded); gradual weakening is invisible, and checking catches it, quantifying the trend;
8) Write pressure raising and leak search into the maintenance card (force calibration); the original failure to raise pressure was the root cause, so closing the loop in maintenance serves as the gate.
GB/T 3766-2015 General technical conditions for hydraulic systems