E44-694 · Hydraulic System Contamination and Crawling · Pressure-Holding Circuits · ★★
After a 5min pressure hold the pressure drops >2MPa (allowed ≤0.3MPa), and the workpiece drifts and loses accuracy
[Mechanism] Internal leakage in the pressure-holding circuit (worn cylinder Glyd rings or a damaged pilot-controlled check valve seat) makes the pressure in the closed volume decay continuously, and the workpiece drifts.
[Calculation] Internal leakage q = Cd·a·√(2Δp/ρ); with Δp=5MPa and a leakage gap a≈0.05mm, q≈0.8L/min, which causes a 5min pressure-hold decay >2MPa (allowed ≤0.3MPa/5min).
[Design Omission] The Glyd-ring seals were not replaced, no pressure-hold test to ≤0.3MPa/5min was performed, and no zero-leakage pilot-controlled check valve was installed to lock the pressure.
1) Replace the cylinder seals (Glyd rings, gap ≤0.05mm); the pressure originally decayed >2MPa in a 5min hold and the workpiece slipped, so new seals restore the pressure hold;
2) Add a pilot-controlled check valve (poppet seat seal, zero leakage); internal leakage decays the pressure, and the locked valve holds it;
3) Verify the pressure-hold time (pressure-hold test, decay ≤0.3MPa/5min); the decay shows up in the hold test, which quantifies it;
4) Check the valve for internal leakage (teardown, replace the seat); internal leakage decays the pressure, and finding and fixing it restores the hold;
5) Control the annular gap (≤0.05mm, boring and plating); a large gap leaks, and controlling it reduces leakage;
6) Monitor the pressure decay rate (sensor, alarm when the rate > threshold); gradual decay is invisible, and monitoring catches it, giving early warning;
7) Choose wear-resistant seals (polyurethane 95A); wear causes leakage, and wear-resistant seals extend life;
8) Write seal replacement and pressure locking into the maintenance card (quarterly check of the check valve); the original failure to replace seals was the root cause, so closing the loop in maintenance serves as the gate.
GB/T 23661-2009 Hydraulic cylinders