E44-691 · Hydraulic System Contamination and Crawling · Hydraulic Systems · ★★★
Shock, vibration, sudden velocity change
[Mechanism] Flow shocks generate pressure oscillation.
[Calculation] A sudden velocity change causes waterhammer shock.
[Design Omission] No cushioning, no relief valve, and no inspection - the root cause of the shock.
1) Add a cushioning valve to slow the actuator (throttle cushioning, decelerate to 0.1m/s); the original reversing velocity change >0.3m/s with shock pressure peaks >25MPa and vibration, so cushioning reduces the shock;
2) Provide a relief valve to discharge the shock (pilot-operated relief, cracking at 20MPa); shock raises the pressure, and relieving it lowers the peak, limiting the pressure;
3) Limit the reversing rate (electrical ramp, ≤0.1s); abrupt reversal causes shock, and ramping eases it, reducing the shock;
4) Add an accumulator to absorb shock (bladder 0.63L, precharged to 8MPa); shock causes vibration, and the accumulator absorbs it, suppressing oscillation;
5) Verify pipe sizing to avoid sudden velocity changes (pipe ID ≥25mm, lower flow velocity); changing conditions cause shock, and correct sizing eases it, stabilizing flow;
6) Monitor shock events (pressure sensor peak, alarm at >22MPa); gradual shock buildup is invisible, and monitoring catches it, giving early warning;
7) Soften start and stop (ramped start/stop); abrupt start/stop causes shock, and ramping reduces it, protecting the piping;
8) Write cushioning and rate limiting into the specification (shock test); the original lack of cushioning was the root cause, so fixing it into the specification serves as the design gate.
GB/T 3766-2015 General technical conditions for hydraulic systems