E44-894 · Throttling Noise and Vibration · Throttling element · ★★★
Saturated liquid at the inlet flashed at the outlet, and the valve stem vibrated 0.6mm
[Mechanism] Throttling drops the pressure below the saturation pressure and the liquid flashes; the two-phase flow pulsates and strikes the valve stem, vibrating it.
[Calculation] p2<pv and a large two-phase density difference; the pulsating force vibrates the stem 0.6mm.
[Design Omission] Flashing was not avoided, the outlet pressure was not verified, and anti-cavitation trim was not fitted.
1) Avoid flashing (raise the outlet pressure above pv or relocate the valve to a subcooled section), since the original p2<pv flashed and vibrated the stem 0.6mm, thus avoiding flashing prevents vibration;
2) Verify the outlet pressure (p2≥pv+0.05), since low pressure vibrates and verification avoids it, thus verifying pressure;
3) Replace with cavitation-resistant trim (tungsten carbide), since two-phase erosion vibrates and the replacement resists it, thus replacing the trim;
4) Use multi-stage reduction (3 stages), since concentration vibrates and splitting eases it, thus staging;
5) Monitor the vibration (measure the stem amplitude, alarm >0.3mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (measure the frequency response), since the lack of testing left the vibration undetected and the test reveals the level, thus testing vibration;
7) Control the temperature to prevent flashing (increase inlet subcooling), since heat causes flashing and control keeps it subcooled, thus controlling temperature;
8) Write the flashing avoidance and pressure verification into the calculation sheet, since the original lack of avoidance is the root cause of vibration and locking it in closes the loop, thus controlling it in the calculation.
GB/T 17213.1-2015 Industrial-process control valves