Acoustic Resonance Pipe

E44-893 · Throttling Noise and Vibration · Pipe section · ★★★

Problem Description

A pipe section resonated acoustically at a specific frequency, producing 92dB(A)

Root Cause

[Mechanism] The pipe section acts as an acoustic cavity; when a throttling-noise frequency equals the cavity's acoustic natural frequency, resonance occurs.
[Calculation] The acoustic natural frequency f=c/2L; the cavity length L happens to amplify the resonance.
[Design Omission] No frequency avoidance, no silencing, no pipe-length change.

Corrective Solution

1) Avoid the acoustic resonance frequency (change the pipe length or add silencing so the frequency moves off the cavity natural frequency), since the original f=c/2L resonated at 92dB(A), thus avoiding the frequency cuts the noise;
2) Verify the frequency separation (noise frequency differs from the cavity frequency by ≥20%), since they resonate when close and verification avoids it, thus checking the separation;
3) Add a silencer (resistive, insertion loss ≥15dB), since the bare pipe resonated at 92dB(A) and silencing lowers it, thus silencing;
4) Change the pipe length to avoid the cavity (adjust it to detune the resonance), since a match causes resonance and changing moves it away, thus changing the length;
5) Monitor the sound (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring sound;
6) Run an acoustic test (measure octave bands), since the lack of testing left the resonance undetected and the test reveals the peak, thus testing sound;
7) Cut the noise at the source (lower Lw), since a strong source resonates and control weakens it, thus controlling the source;
8) Write frequency avoidance and silencing into the specification, since the original lack of avoidance is the root cause of resonance and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL