E44-895 · Throttling Noise and Vibration · High-pressure throttling element · ★★★

Problem Description

Throttling at a 10MPa inlet produced 98dB(A), exceeding the plant boundary limit

Root Cause

[Mechanism] High-pressure throttling with a large pressure drop reaches choked flow, and the sound power becomes very high.
[Calculation] Δp=9MPa and x=0.1<0.5 give choked flow, Lw≈120dB.
[Design Omission] No staged pressure reduction, no multi-stage trim, no silencing.

Corrective Solution

1) Reduce the pressure in stages to cut noise (5 stages each dropping 1.8MPa, stage x>0.5), since the original Δp9MPa and x=0.1 gave choked flow at 98dB(A), thus staging cuts the noise;
2) Verify the sound level (≤85dB(A)), since exceeding it is a nuisance and verification confirms compliance, thus checking the sound;
3) Use multi-stage trim (5-stage cage), since concentrating the drop makes noise and splitting eases it, thus staging;
4) Add a silencer (insertion loss ≥20dB), since the bare element radiates 98dB(A) and silencing lowers it, thus silencing;
5) Monitor the noise (sound-level meter, alarm >85dB(A)), since gradual growth approaches the limit and early detection catches it, thus monitoring noise;
6) Run an acoustic test (measure Lw), since the lack of testing left the noise undetected and the test reveals the level, thus testing sound;
7) Control the flow to steady the speed (limit v), since changing conditions make noise and control steadies it, thus controlling speed;
8) Write staged reduction and silencing into the specification, since the original lack of staging is the root cause of noise and locking it in closes the loop, thus controlling it in the spec.