MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Missing Throttling Noise Control

Missing Throttling Noise Control

E44-896 · Throttling Noise and Vibration · Throttling system · ★★★

Problem Description

No noise control anywhere in the system; the plant boundary reached 98dB(A), exceeding the limit

Root Cause

[Mechanism] No noise prediction or control was done at the design stage, so the throttling noise has no mitigation.
[Calculation] The throttling points add up to 98dB(A) at the plant boundary, 13dB over the GB12348 limit.
[Design Omission] No mitigation, no silencing, no insulation.

Corrective Solution

1) Add noise-control measures, since there were none originally, thus retrofitting reduces noise;
2) Verify the sound level ≤ the standard, since exceeding it is a nuisance, thus checking the sound;
3) Add silencers, since exposed parts radiate noise, thus silencing;
4) Add acoustic lagging, since exposed surfaces transmit noise, thus lagging;
5) Monitor the noise state, since it grows gradually, thus noise monitoring;
6) Run an acoustic test, since the lack of testing let the noise go unnoticed, thus testing sound;
7) Steady the flow at the source, since changing conditions produce noise, thus controlling the source;
8) Write retrofit silencing into the specification, since the original lack of mitigation is the root cause of noise, thus controlling it in the spec.

Checklist

Reference

GB/T 3767-2016 Determination of sound power levels of noise sources using sound pressure

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL