E44-924 · Siphon and Backflow · Break Valve · ★★
Spurious tripping, lost suction, flow stoppage
[Mechanism] The vacuum break valve's opening/closing pressure is set wrong or its diaphragm has degraded, so it opens spuriously during operation, breaks the vacuum, and interrupts the siphon.
[Calculation] A setting 0.015 MPa too low makes the valve open spuriously on normal fluctuation, breaking the vacuum and stopping the flow; the diaphragm has a 1-year fatigue life.
[Design Omission] The opening/closing pressure was not checked, a fatigue-resistant type was not selected, and there was no status monitoring.
1) Check the opening/closing pressure so the valve opens only when the vacuum drops to 0.5 m on pump stop (originally set low and tripping spuriously), because a correct setting keeps normal fluctuation from triggering it and stops the spurious opening, thereby keeping the siphon continuous;
2) Replace with a fatigue-resistant diaphragm (life extended from 1 year to 3 years), because the original degraded diaphragm tripped spuriously while the new one is stable, thereby making the valve reliable;
3) Add a damping restrictor ahead of the valve to prevent pressure-fluctuation false triggering, because transient fluctuation causes spurious opening and damping steadies it, thereby preventing spurious tripping;
4) Transmit the valve position remotely with an alarm (alarm on spurious opening), because spurious tripping first shows as an abnormal status before flow stoppage, thereby monitoring the valve for early warning;
5) Perform a spurious-trip test (verify no false opening under fluctuating conditions), because the design omitted the pressure check and the test confirms whether it trips spuriously, thereby setting the pressure from data;
6) Provide two valves in parallel (one duty, one standby), because a single degraded valve trips spuriously while dual valves keep one reliable, thereby providing redundancy against false tripping;
7) Send the valve-open signal only on pump stop (interlocked rather than passive), because active control is more stable than passive and the sequence prevents error, thereby controlling the opening to prevent mistakes;
8) Write the opening/closing pressure check into the specification, because the root cause of the spurious tripping is a wrong setting combined with diaphragm degradation, so the specification must govern to prevent spurious opening.
GB/T 20801.3-2020 Design code for industrial metallic piping