E44-925 · Siphon and Backflow · Pump · ★★★
Backflow, cavitation, damage
[Mechanism] After the pump stops, the backflow of medium makes the pump inlet pressure fluctuate abnormally, and the local negative pressure induces cavitation.
[Calculation] Backflow plunges the inlet pressure from 0.15 MPa to -0.02 MPa, below the 0.024 MPa vapor pressure, vaporizing the liquid and causing cavitation.
[Design Omission] No check valve at the inlet, no inlet-pressure check, and no buffer.
1) Install a check valve at the pump inlet (tight shutoff, zero leakage), because backflow plunges the inlet pressure and the check valve cuts off the reverse flow and keeps positive pressure, thereby preventing negative pressure at the inlet;
2) Provide a buffer tank at the inlet (hold the inlet pressure fluctuation ≤0.01 MPa), because backflow causes abrupt pressure changes and the tank absorbs and shaves them to hold the pressure, thereby suppressing cavitation;
3) Check the inlet NPSHa ≥ NPSHr + 0.5 m (originally NPSHa dropped from 2.1 m to -0.2 m during backflow), because an adequate margin avoids vaporization and eliminates cavitation, thereby maintaining the margin;
4) Provide a slow-closing check valve at the outlet (to stop the backflow at its source), because backflow is the cause of the inlet pressure drop and cutting it off steadies the inlet, thereby removing the trigger;
5) Fit the inlet with a vacuum gauge and alarm (alarm below <0.05 MPa), because approaching vaporization first shows as an inlet pressure drop and allows early intervention, thereby monitoring the pressure to prevent cavitation;
6) Perform a backflow cavitation test (verify the inlet pressure does not drop below vaporization), because the design omitted the pressure check and the test confirms the margin, thereby sizing the tank volume from data;
7) Interlock the pump stop sequence to close the outlet before stopping, because a wrong sequence causes backflow and controlling it suppresses the pressure change, thereby controlling the stop to prevent cavitation;
8) Write the inlet check valve and NPSHa checking into the pump regulations, because the root cause of cavitation is backflow-induced negative inlet pressure, so the regulations must govern to prevent cavitation.
GB/T 5657-1995 Technical specifications for centrifugal pumps