E44-926 · Siphon and Backflow · Siphon Pipe · ★★
Empty water seal, backflow, contamination
[Mechanism] The siphon vacuum draws the liquid column out of the U-shaped water seal, the liquid seal is lost, and gas or medium from downstream surges back.
[Calculation] The suction of the -0.08 MPa siphon vacuum pulls the seal liquid column up 1.0 m, and the original 0.3 m seal height is too low and is drawn empty.
[Design Omission] Insufficient water seal height, no makeup water, and no breather to break the vacuum.
1) Raise the water seal height to ≥1.0 m (originally 0.3 m), because the seal withstands pressure = ρgh, and 1.0 m resists 0.01 MPa > the 0.008 MPa suction, thereby preventing it from being drawn empty;
2) Provide a breather at the seal top (break the vacuum to keep the seal), because negative pressure draws the seal and the breather breaks the vacuum to lower the suction and hold the level, thereby keeping the seal from being drained dry;
3) Provide an overflow makeup-water pipe to the water seal (always full), because the siphon keeps drawing it off and makeup water keeps it full, thereby keeping the seal in place;
4) Add a check valve ahead of the water seal to block backflow positive pressure, because positive pressure adds to the suction and breaks the seal while the check valve cuts the positive pressure, thereby protecting the seal;
5) Perform a water-seal suction-resistance test (verify it is not drawn empty), because the design omitted the height check and the test confirms the suction resistance, thereby determining the seal height from data;
6) Provide a seal level gauge with a low alarm (<0.8 m), because the seal drops before it empties and allows early makeup, thereby monitoring the seal to keep it from emptying;
7) Provide pressure relief on the backflow side (relieve on overpressure), because overpressure aids the suction and breaks the seal while relief lowers the positive pressure, thereby protecting the seal;
8) Write the water seal height and breather vacuum breaking into the installation card, because the root cause of the seal being drawn empty is a low seal without a breather, so installation must govern to prevent surging.
GB/T 20801.3-2020 Design code for industrial metallic piping