E44-923 · Siphon and Backflow · Pump · ★★★
Backflow, reverse rotation, damage
[Mechanism] After the pump stops the outlet check valve fails, and the backflow of medium from the higher level drives the pump impeller in reverse, damaging the bearings and seals.
[Calculation] A backflow head of H=22 m produces reverse rotation n_rev≈1.3n_n and a reverse torque reaching 30% of rated, with the seal face speed exceeding the limit and causing damage.
[Design Omission] The check valve failure was not detected, no slow closing was provided, and there was no reverse-rotation protection.
1) Install a slow-closing check valve at the pump outlet (closing in 3~5 s, seepage ≤5 mL/min), because reverse rotation is caused by valve leakage and slow closing eases the velocity change and cuts the reverse torque by 70%, thereby preventing reverse rotation;
2) Overhaul the check valve every quarter to keep it sealing, because a worn spool fails and leaks, causing backflow, and strict inspection keeps it leak-free, thereby cutting off the reverse-rotation source;
3) Add pump reverse-rotation protection (audible and visual alarm and power cut if n>10% of rated), because reverse rotation damages the bearings and monitoring cuts it off at once, thereby preventing reverse-rotation damage;
4) Provide an air buffer tank at the outlet (volume ≥ flow × 5 s), because the tank absorbs and eases the backflow velocity and reduces the reverse torque, thereby cushioning and protecting the pump;
5) Fit the outlet with a speed sensor and reverse-rotation alarm (stop on alarm), because reverse rotation first shows as reversed speed before damage, thereby monitoring the speed for early warning;
6) Perform a pump-stop reverse-rotation test (measure the reverse speed), because the design omitted the slow-closing check and the test confirms whether reverse rotation occurs, thereby selecting the valve type from data;
7) Interlock the pump stop sequence to close the outlet valve before stopping the pump, because stopping first causes backflow and reverse rotation and controlling the sequence suppresses it, thereby controlling the stop to prevent reversal;
8) Write the slow-closing check valve and reverse-rotation protection into the pump station regulations, because the root cause of reverse rotation is a failed check valve without slow closing, so the regulations must govern to prevent reverse rotation.
GB/T 5657-1995 Technical specifications for centrifugal pumps