Wrong Distributor Design

E44-740 · Uneven Flow Distribution · Distributor · ★★

Problem Description

Wrong design, uneven distribution

Root Cause

[Mechanism] A wrong design leaves the distribution uneven.
[Calculation] The orifice error causes the uneven distribution.
[Design Omission] No verification calculation, no testing, and no inspection were provided, so the design is wrong.

Corrective Solution

1) Recheck the distributor hydraulics (verify the resistance of each outlet, even distribution), because the original error left the outlet flows differing by >20%, thereby rechecking to restore evenness;
2) Run a distribution test (dye visualization, accept when even), because the lack of testing caused the error and testing verifies it, thereby testing the distribution;
3) Modify the distribution structure (add a distribution chamber, equalize pressure), because a wrong structure leaves the distribution uneven and modification evens it, thereby modifying the structure;
4) Verify the resistance of each outlet (per outlet, difference ≤3%), because a difference leaves the distribution uneven and verification evens it, thereby verifying the resistance;
5) Standardize the outlet diameters (same diameter at every outlet), because a difference causes error and standardization evens it, thereby standardizing the outlets;
6) Monitor the distribution (sample at each outlet, alarm above 10%), because gradual unevenness is invisible and monitoring catches it, thereby giving early warning;
7) Keep the total flow steady (steady pump), because changing conditions cause error and control steadies them, thereby steadying the total flow;
8) Write the verification calculation and distribution test into the specification (distribution uniformity), because the design omitted the calculation and that was the root cause, thereby freezing it into the specification enforces control.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping