Knowledge Base › Fluid Systems Error Case › Wrong Slope Direction of a Siphon Pipe

Wrong Slope Direction of a Siphon Pipe

E44-939 · Siphon and Backflow · Siphon Pipe · ★★

Problem Description

Wrong slope direction, air accumulation, flow stoppage

Root Cause

[Mechanism] The siphon pipe is laid on an adverse slope, so air accumulates at the high point and forms an air lock that stops the flow.
[Calculation] With the adverse slope i=-0.004 (should be ≥0.003 favorable), every 10 m of pipe traps 0.3 L of air; the air-lock resistance rises 3 times, and the flow drops 60% and stops.
[Design Omission] No favorable slope, no slope-direction check, and no high-point venting.

Corrective Solution

1) Change to a favorable slope layout i≥0.003 (originally i=-0.004), because an adverse-slope layout is the root cause of the air pocket and a favorable slope lets air drain with the flow, thereby clearing the pipe top of accumulation and eliminating the flow stoppage;
2) Check the slope direction by measuring the elevation section by section (≤0.03 m difference per 10 m), because a wrong slope direction traps air and checking it keeps the slope favorable, thereby ensuring the correct slope direction;
3) Install automatic vent valves at the high points (venting on air accumulation, capacity ≥0.5 m³/h), because multi-point air collection restricts flow and venting restores it, thereby eliminating the air lock;
4) Raise the flow velocity to 1.3 m/s (originally 0.9 m/s), because air tends to stagnate at low velocity and a higher velocity carries it out, thereby suppressing accumulation;
5) Perform a water-filling air-lock test (fill the pipe and verify full passage), because the design omitted the slope check and the test confirms the air is cleared, thereby determining the slope direction from data;
6) Monitor the total flow in operation (alarm if it drops >20%), because air accumulation first shows as a flow drop before stoppage, thereby monitoring the flow for early warning;
7) Remove the local humps on the pipe top (hump height ≤10 mm), because air collects at the humps and removing them keeps the run smooth, thereby smoothing the pipe top;
8) Write the favorable slope and venting into the installation card, because the root cause of the slope error is an adverse slope without venting, so installation must govern to prevent flow stoppage.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »