Knowledge Base › Fluid Systems Error Case › Electromagnetic Flowmeter Cavitation

Electromagnetic Flowmeter Cavitation

E44-1116 · Miscellaneous · Magnetic Flowmeter · ★★

Problem Description

Erosion, reading, offset

Root Cause

[Mechanism] The electromagnetic flowmeter is mounted where back-pressure is low, so the medium vaporizes and bubbles disturb the sensing signal, biasing the reading.
[Calculation] Back-pressure is 0.05MPa (should be ≥0.2); vaporization makes the signal fluctuate ±10%, and the reading error reaches 8% (should be ≤1).
[Design Omission] No air vent, no back-pressure control, no full-pipe check, and no accuracy test.

Corrective Solution

1) Install an air vent (at the high point), since vapor causes error and venting restores accuracy, restoring true reading;
2) Hold back-pressure ≥0.2MPa (raise back-pressure), since low pressure causes vaporization and adequate pressure stabilizes it, suppressing vapor;
3) Check for a full pipe (install full-bore), since a partially filled pipe biases the reading and a full pipe reads true, giving accurate indication;
4) Stabilize the flow (straight run ≥10D), since pulsation causes error and steady flow reads true, stabilizing the signal;
5) Run an accuracy test (error ≤1%), since without proof accuracy is unknown and a measured test confirms it, setting indication on data;
6) Fit signal monitoring (alarm on fluctuation), since cavitation first shows as signal noise for early warning, monitoring erosion;
7) Set an inspection interval (every six months), since long service causes erosion and scheduled inspection prevents it, guarding against vapor in service;
8) Write venting and back-pressure control into the flowmeter drawing, since the bias stems from low back-pressure plus no vent, closing the loop at the drawing.

Checklist

Reference

GB/T 2624.1-2006 Flow measurement