E44-775 · Uneven Flow Distribution · Local-Resistance Fittings · ★★
A sudden increase in local resistance cut that branch's flow >15%
[Mechanism] The selection or layout of local-resistance fittings causes an abrupt change.
[Calculation] The abrupt change raises that branch's ζ and cuts its flow >15%.
[Design Omission] Nothing was made gradual and nothing was verified, so it had to be made gradual.
1) Make the cross-section change gradual to avoid abruptness (use a long tapered transition, taper ≤1:7), because the original abrupt change made that branch's local-resistance coefficient ζ jump and cut its flow >15%, thereby flattening the resistance through a gradual change;
2) Calibrate the local resistance (measure each branch's ζ and compare with the design), because off-design conditions bias it and calibration reveals it, thereby verifying the resistance by measurement;
3) Use the same fitting type (use the same type of resistance fitting on the same branch to reduce differences), because a difference causes the change and uniformity flattens it, thereby reducing the difference by uniformity;
4) Equalize the resistance of the branches (adjust the balance valves to make up the local difference), because a difference biases the flow and equalizing balances it, thereby distributing the flow evenly by equalizing resistance;
5) Monitor the deviation (monitor each branch's flow, alarm above 10% deviation), because the deviation grows gradually and starves some branches and monitoring gives early warning, thereby monitoring the deviation;
6) Run a flow test (trace the flow field at the abrupt change), because the omitted test let the bias go unnoticed, thereby proving even distribution;
7) Control the total pressure (keep the total pressure steady against amplified abruptness), because off-design conditions worsen the bias and stabilization soothes it, thereby stabilizing the pressure;
8) Write the gradual transitions and resistance calibration into the calculation report, because the omitted gradualness was the root cause of the change and the report enforces it, keeping the local resistance even.
GB/T 20801.3-2020 Design code for industrial metallic piping