Knowledge Base › Fluid Systems Error Case › Measurement Error from a Wrong Flowmeter Location

Measurement Error from a Wrong Flowmeter Location

E44-774 · Uneven Flow Distribution · Flowmeter · ★★

Problem Description

Wrong meter location, measurement off >3%, control biased

Root Cause

[Mechanism] Insufficient straight pipe upstream/downstream or installation against the flow direction.
[Calculation] An upstream straight run <5D distorts the flow field and biases the measurement >3%.
[Design Omission] The location was not specified and not calibrated, so it was wrong.

Corrective Solution

1) Redefine the installation location (upstream straight run ≥10D, downstream ≥5D, full-pipe section), because the original upstream straight run <5D distorted the flow field, biased the measurement >3%, and threw the control off, thereby restoring accuracy by relocating the meter;
2) Preserve the upstream straight section (relocate the meter or add a straight run), because a short run distorts the flow and preserving the section keeps it accurate, thereby restoring the measurement;
3) Calibrate the flow (actual-flow calibration ±0.5%), because an error distorts the flow and calibration keeps it accurate, thereby restoring the flow accuracy;
4) Install in the flow direction (arrow pointing with the incoming flow), because reverse installation distorts the flow and correct orientation keeps it accurate, thereby restoring the measurement;
5) Check the location (monitor the pressure difference across the meter or the flow regime), because gradual error widens the bias and early detection helps, thereby checking the location;
6) Run a flow test (trace the flow field upstream of the meter), because the omitted test let the distortion go unnoticed, thereby proving a steady field;
7) Control the total pressure (keep the total flow steady against amplified distortion), because off-design conditions worsen the bias and stabilization soothes it, thereby stabilizing the pressure;
8) Write the location definition and straight-run preservation into the assembly card, because the undefined location was the root cause and the assembly card enforces it, keeping the measurement accurate and control right.

Checklist

Reference

GB/T 2624.1-2006 Flow measurement