Knowledge Base › Fluid Systems Error Case › Biased Flow from Thermometer Insertion

Biased Flow from Thermometer Insertion

E44-773 · Uneven Flow Distribution · Thermometer Well · ★★

Problem Description

Insertion depth disturbed the flow, measurement off >2℃, local separation

Root Cause

[Mechanism] The insertion depth or counter-flow insertion disturbs the flow.
[Calculation] An insertion depth over one third of the pipe diameter distorts the local velocity and biases the measurement >2℃.
[Design Omission] The position was not defined and the insertion was not kept shallow, so it was wrong.

Corrective Solution

1) Define a shallow insertion position (insertion depth ≤ one third of the pipe diameter, oblique insertion downstream), because the original depth over one third of the pipe diameter distorted the local velocity, biased the measurement >2℃, and disturbed the downstream distribution, thereby reducing the disturbance by shallow insertion;
2) Choose downstream insertion (sensing tip facing downstream to reduce swirl), because counter-flow insertion disturbs the flow and downstream insertion steadies it, thereby reducing swirl;
3) Verify the straight run of the measurement section (upstream and downstream runs ≥10D), because a short run leaves the flow unsettled and biases the measurement, thereby restoring accuracy;
4) Limit the insertion depth (add a stop sleeve to prevent over-insertion), because deep insertion disturbs the flow and a limit prevents it, thereby steadying the flow;
5) Check the flow regime (observe the flow or measure the deviation downstream of the well), because gradual disturbance widens the deviation and early detection helps, thereby checking the flow;
6) Run a flow test (trace the flow field downstream of the well), because the omitted test let the disturbance go unnoticed, thereby proving a steady flow;
7) Control the total pressure (keep the total flow steady against amplified disturbance), because off-design conditions worsen the disturbance and stabilization soothes it, thereby stabilizing the pressure;
8) Write the position definition and shallow insertion into the assembly card, because the undefined position was the root cause and the assembly card enforces it, leaving the flow undisturbed.

Checklist

Reference

GB/T 2624.1-2006 Flow measurement