E44-772 · Uneven Flow Distribution · Filter · ★★
Filter plugged, Δp rose >0.1MPa, biased flow
[Mechanism] A plugged filter element raises that branch's resistance and biases the flow.
[Calculation] The plugging raises the Δp >0.1MPa and cuts that branch's flow >20%.
[Design Omission] Nothing was cleaned, no bypass was provided, and nothing was inspected, so the filter plugged.
1) Clean the filter to clear the plugging (remove and wash the strainer or replace the cartridge), because the plugging raised that branch's Δp >0.1MPa and cut its flow >20%, biasing the flow, thereby restoring even flow by cleaning;
2) Provide a differential-pressure alarm (alarm above Δp >0.08MPa), because a high Δp means plugging and early alarms allow early cleaning, thereby warning early;
3) Add a bypass to maintain flow (switch to the bypass to keep a minimum flow when plugged), because plugging stops the flow and the bypass preserves it, thereby preventing flow loss;
4) Increase the dirt-holding capacity (choose a high-capacity element or dual filters), because a small one plugs easily and a large one lasts longer, thereby extending the interval;
5) Check for plugging (monitor the differential pressure, alarm above a rise rate of 5%/d), because gradual plugging widens the bias and early detection helps, thereby monitoring for plugging;
6) Control media cleanliness (add a coarse filter upstream against large particles), because dirt plugs the filter and pre-filtration prevents it, thereby controlling cleanliness;
7) Replace the element at intervals (replace by differential pressure or schedule), because long service plugs the filter and periodic replacement prevents it, thereby preventing plugging;
8) Write the cleaning and bypass into the maintenance card, because the omitted cleaning was the root cause of the plugging and the maintenance card enforces it, suppressing biased flow.
GB/T 20801.3-2020 Design code for industrial metallic piping